학술논문

Worldwide Comparison of Lightning Impulse Voltage Measuring Systems at the 400-kV Level.
Document Type
Article
Source
IEEE Transactions on Instrumentation & Measurement. Apr2007, Vol. 56 Issue 2, p388-391. 4p. 2 Black and White Photographs, 1 Diagram, 6 Graphs.
Subject
*Universities & colleges
*Instrument industry
Paper
Measurement
Electric potential
Public institutions
Language
ISSN
0018-9456
Abstract
An international comparison of lightning and switching impulse voltage measuring systems was arranged and coordinated by the Helsinki University of Technology (MIKES-TKK), Espoo, Finland, between 1999 and 2002. The number of participants was 26, including the coordinator. This paper summarizes the results obtained by those eight National Metrology Institutes that participated in the comparison. A 400-kV transfer reference measuring system for measuring lightning impulse voltages was prepared by the coordinator. In addition, a 1-kV impulse voltage calibrator system, including calibrators for both standard lightning and switching impulses, was circulated. [ABSTRACT FROM AUTHOR]