학술논문

Safety of a High-Efficiency Electrical Fence Energizer
Document Type
Conference
Source
2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) Engineering in Medicine & Biology Society (EMBC), 2020 42nd Annual International Conference of the IEEE. :5016-5020 Jul, 2020
Subject
Bioengineering
Electric fences
Safety
Resistance
Resistors
IEC Standards
Capacitors
Language
ISSN
2694-0604
Abstract
Introduction: Our primary goal was to evaluate the performance of a new high-efficiency electric fence energizer unit using resistive load changes. Our secondary goal was to test for compliance with the classical energy limits and the newer charge-based limits for output. Methods: We tested 4 units of the Nemtek Druid energizer with 2 channels each. We used a wide load-resistance range to cover the worst-case scenario of a barefoot child making a chest contact (400 Ω) up to an adult merely touching the fence (2 kΩ). Results: The energy output was quite consistent between the 8 sources. Even at the lowest resistance, 400 Ω, the outputs were well below the IEC 60335-2-76 limit of 5 J/pulse. The charge delivered was also quite consistent. Even at the lowest resistance, 400 Ω, the outputs (679 ± 23 µC) were well below the proposed limits of 4 mC for short pulses. Conclusions: The high-efficiency electric fence energizers satisfied all relevant safety limits. Charge, energy, voltage, and current outputs were consistent between channels and units.