학술논문

Pulsed, high energy testing of resistors
Document Type
Conference
Source
Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358) Pulsed power conference Pulsed Power Conference, 1999. Digest of Technical Papers. 12th IEEE International. 2:712-715 vol.2 1999
Subject
Power, Energy and Industry Applications
Resistors
Voltage
Pulse measurements
System testing
Pulse generation
Pulse transformers
Electrical resistance measurement
Spark gaps
Probes
Laboratories
Language
Abstract
Three types of resistors have been tested to determine maximum usable power at pulsed high voltage and pulsed high current. Experiments were carried out using high voltage cable generators and spark-gap generators. Pulse durations were varied from 0.7 /spl mu/s to 21 /spl mu/s. The pulse amplitudes were varied from 1 kV to 12 kV. The peak current reached was 3 kA. Metal film, carbon film and carbon composition resistors of four different rated powers (0.25 W, 0.5 W, 1 W, 2 W) have been tested. Data are given for the limiting pulsed energy for each type of resistor in nanosecond and microsecond time ranges. The mechanisms of failure and destruction of resistors under the action of high voltage and high current pulses are discussed.