학술논문

New beam diagnostic developments at the Photo-Injector Test Facility PITZ
Document Type
Conference
Source
2007 IEEE Particle Accelerator Conference (PAC) Particle Accelerator Conference, 2007. PAC. IEEE. :3967-3969 Jun, 2007
Subject
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Nuclear Engineering
Robotics and Control Systems
Test facilities
Laser beams
Dispersion
Particle beams
Electron sources
Energy measurement
Electron accelerators
Brightness
Radio frequency
Tomography
Language
ISSN
1944-4680
2152-9582
Abstract
The Photo-Injector Test Facility at DESY in Zeuthen (PITZ) is an electron accelerator which was built to develop and optimize high brightness electron sources suitable for SASE FEL operation. Currently, in parallel to the operation of the existing setup, a large extension of the facility and its research program is ongoing. The beam line which has a present length of about 13 meters will be extended up to about 21 meters within the next year. Many additional diagnostics components will be added to the present layout. Two high-energy dispersive arms, an RF deflecting cavity and a phase space tomography module will extend the existing diagnostic system of the photo injector and will contribute to the full characterization of new electron sources. We report on the latest developments of the beam diagnostics at PITZ.