학술논문

100 bunch DA/spl Phi/NE operation
Document Type
Conference
Source
Proceedings of the 2003 Particle Accelerator Conference Particle accelerator conference Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the. 1:366-368 Vol.1 2003
Subject
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Nuclear Engineering
Robotics and Control Systems
Nonlinear optics
Optical feedback
Optical saturation
Frequency
Electrons
Detectors
Stimulated emission
Magnets
Tuning
Apertures
Language
ISSN
1063-3928
Abstract
The DA/spl Phi/NE collider has been operating by filling 100 consecutive buckets out of the available 120 with a gap to avoid ion trapping in the electron beam. To reduce the effect of the parasitic crossings the crossing angle has been increased up to 29 mrad and the horizontal beta function at the interaction point lowered down to 1.7 m. Moreover both transverse and longitudinal feedbacks have been optimized for this more demanding mode of operation. Comparison between 100 and 50 bunches operation in 2002 runs is presented.