학술논문

Sapphire Fiber Bragg Gratings Demodulated With Cross Correlation Algorithm for Long-Term High-Temperature Measurement
Document Type
Periodical
Source
IEEE Sensors Journal IEEE Sensors J. Sensors Journal, IEEE. 24(6):7905-7911 Mar, 2024
Subject
Signal Processing and Analysis
Communication, Networking and Broadcast Technologies
Components, Circuits, Devices and Systems
Robotics and Control Systems
Temperature measurement
Optical fiber sensors
Sensors
Thermal stability
Temperature sensors
Reflection
Electron tubes
Cross correlation algorithm (CCA)
high-temperature measurement
sapphire fiber Bragg grating (SFBG)
Language
ISSN
1530-437X
1558-1748
2379-9153
Abstract
The sapphire fiber Bragg grating (SFBG) is a promising high-temperature sensor for application in aviation and power industries; however, the multimode characteristics of SFBG result in a broadband reflection envelope, including multiple peaks, which have a strong impact on the sensing accuracy. In this article, we propose and experimentally demonstrate a cross correlation algorithm (CCA) for the demodulation of SFBG, with the benefit of enhancing the stability of wavelength detection, and hence, the sensing accuracy can be improved. The SFBG high-temperature sensor was created by using the femtosecond laser line-by-line method and sealed in an argon gas-infiltrated sapphire tube. Such a device was demodulated by using the CCA, and the findings show that the Bragg wavelength dispersion of ±12 pm could be obtained; furthermore, before the calibration process, the SFBG sensor was annealed at 1500 °C for 50 h to enhance the stability of reflection spectrum. The temperature calibration experiment has been carried out. In that case, a dry-block calibrator with high stability was employed to calibrate the temperature uncertainty of SFBG is ±0.7 °C. Compared to the calibrated thermometer, the maximum difference is less than 2 °C. In that case, a tube furnace was used to test the SFBG; the temperature uncertainty increased to 2.2 °C, and the maximum difference increased to 7 °C. This is due to the larger temperature fluctuation of this tube furnace. A 1000-h (i.e., 42 days), 1500 °C stability test was carried out. The SFBG exhibited excellent long-term high thermal stability (temperature deviation less than 2.0 °C). A cycling temperatures test was performed, which exhibited good repeatability in temperature measurements. Hence, such an SFBG sensor and the demodulation algorithm are prospectives for applications in harsh environments.