학술논문

Broken Bar Fault Detection in IM Operating Under No-Load Condition
Document Type
article
Source
Advances in Electrical and Computer Engineering, Vol 16, Iss 4, Pp 63-70 (2016)
Subject
fault detection
current measurement
fast Fourier transform
induction motor
spectral analysis
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Computer engineering. Computer hardware
TK7885-7895
Language
English
ISSN
1582-7445
1844-7600
Abstract
This paper presents a novel method for broken rotor bar detection in a squirrel-cage induction motor (IM). The proposed method applies a single-phase AC voltage as a test signal on motor terminals, resulting in a stator backward-rotating magnetic field. The field ultimately causes additional current components in the stator windings whose magnitudes depend on the broken bar fault severity, even if the motor is unloaded. This allows robust broken bar fault detection based only on standard motor current signature analysis (MCSA) technique. The proposed fault detection method is at first verified via simulations, using an IM model based on finite element analysis (FEA) and multiple coupled circuit approach (MCCA). The subsequent experimental investigations have shown good agreement with both theoretical predictions and simulation results.