학술논문

Development of an Artificial Intelligence–Based Automated Recommendation System for Clinical Laboratory Tests: Retrospective Analysis of the National Health Insurance Database
Document Type
article
Source
JMIR Medical Informatics, Vol 8, Iss 11, p e24163 (2020)
Subject
Computer applications to medicine. Medical informatics
R858-859.7
Language
English
ISSN
2291-9694
Abstract
BackgroundLaboratory tests are considered an essential part of patient safety as patients’ screening, diagnosis, and follow-up are solely based on laboratory tests. Diagnosis of patients could be wrong, missed, or delayed if laboratory tests are performed erroneously. However, recognizing the value of correct laboratory test ordering remains underestimated by policymakers and clinicians. Nowadays, artificial intelligence methods such as machine learning and deep learning (DL) have been extensively used as powerful tools for pattern recognition in large data sets. Therefore, developing an automated laboratory test recommendation tool using available data from electronic health records (EHRs) could support current clinical practice. ObjectiveThe objective of this study was to develop an artificial intelligence–based automated model that can provide laboratory tests recommendation based on simple variables available in EHRs. MethodsA retrospective analysis of the National Health Insurance database between January 1, 2013, and December 31, 2013, was performed. We reviewed the record of all patients who visited the cardiology department at least once and were prescribed laboratory tests. The data set was split into training and testing sets (80:20) to develop the DL model. In the internal validation, 25% of data were randomly selected from the training set to evaluate the performance of this model. ResultsWe used the area under the receiver operating characteristic curve, precision, recall, and hamming loss as comparative measures. A total of 129,938 prescriptions were used in our model. The DL-based automated recommendation system for laboratory tests achieved a significantly higher area under the receiver operating characteristic curve (AUROCmacro and AUROCmicro of 0.76 and 0.87, respectively). Using a low cutoff, the model identified appropriate laboratory tests with 99% sensitivity. ConclusionsThe developed artificial intelligence model based on DL exhibited good discriminative capability for predicting laboratory tests using routinely collected EHR data. Utilization of DL approaches can facilitate optimal laboratory test selection for patients, which may in turn improve patient safety. However, future study is recommended to assess the cost-effectiveness for implementing this model in real-world clinical settings.