Reliability of Echocardiographic Indices of Dyssynchrony.
Document Type
Article
Source
Echocardiography. Jan2007, Vol. 24 Issue 1, p40-46. 7p. 7 Charts.
Subject
*ECHOCARDIOGRAPHY
*ARRHYTHMIA treatment
*CARDIAC pacing
*DOPPLER echocardiography
*MEDICAL screening
*CARDIAC patients
Language
ISSN
0742-2822
Abstract
Background: Echocardiographic indices of dyssynchrony are increasingly used to select candidates for cardiac resynchronization therapy. For widespread screening of heart failure patients, such variables need to be comparable when evaluated by different operators using different equipment. Objective and Methods: To evaluate the reproducibility and obtainability of echocardiographic indices of mechanical dyssynchrony, we studied 40 subjects stratified according to QRS morphology and systolic function. Two echocardiograms were performed on each patient by different sonographers on different machines and each study was analyzed by two observers. Results: All blood-pool and tissue Doppler indices of dyssynchrony were obtainable in over 97% of cases. Blood-pool Doppler measures were the most reproducible indices of intraventricular dyssynchrony (aortic ejection delay) and interventricular dyssynchrony (aortopulmonary difference in ejection delay). For annular tissue Doppler delays, the time to peak velocity was consistently more reproducible than the time to velocity onset. Conclusion : Differences in the reliability of echocardiographic indices may affect their suitability as screening tests for dyssynchrony. [ABSTRACT FROM AUTHOR]