학술논문

Results of a long-term international comparison of greenhouse gas and isotope measurements at the Global Atmosphere Watch (GAW) Observatory in Alert, Nunavut, Canada.
Document Type
Article
Source
Atmospheric Measurement Techniques. 2023, Vol. 16 Issue 23, p5909-5935. 27p.
Subject
*ATMOSPHERIC carbon dioxide
*GREENHOUSE gases
*CARBON dioxide
*OBSERVATORIES
*STABLE isotopes
Language
ISSN
1867-1381
Abstract
Since 1999, Environment and Climate Change Canada (ECCC) has been coordinating a multi-laboratory comparison of measurements of long-lived greenhouse gases in whole air samples collected at the Global Atmosphere Watch (GAW) Alert Observatory located in the Canadian High Arctic (82 ∘ 28 ′ N, 62 ∘ 30 ′ W). In this paper, we evaluate the measurement agreement of atmospheric CO 2 , CH 4 , N 2 O, SF 6 , and stable isotopes of CO 2 (δ13 C, δ18 O) between leading laboratories from seven independent international institutions. The measure of success is linked to target goals for network compatibility outlined by the World Meteorological Organization's (WMO) GAW greenhouse gas measurement community. Overall, based on ∼ 8000 discrete flask samples, we find that the co-located atmospheric CO 2 and CH 4 measurement records from Alert by CSIRO, MPI-BGC, SIO, UHEI-IUP, and ECCC versus NOAA (the designated reference laboratory) are generally consistent with the WMO compatibility goals of ± 0.1 ppm CO 2 and ± 2 ppb CH 4 over the 17-year period (1999–2016), although there are periods where differences exceed target levels and persist as systematic bias for months or years. Consistency with the WMO goals for N 2 O, SF 6 , and stable isotopes of CO 2 (δ13 C, δ18 O) has not been demonstrated. Additional analysis of co-located comparison measurements between CSIRO and SIO versus NOAA or INSTAAR (for the isotopes of CO 2) at other geographical sites suggests that the findings at Alert for CO 2 , CH 4 , N 2 O, and δ13 C–CO 2 could be extended across the CSIRO, SIO, and NOAA observing networks. The primary approach to estimate an overall measurement agreement level was carried out by pooling the differences of all individual laboratories versus the designated reference laboratory and determining the 95th percentile range of these data points. Using this approach over the entire data record, our best estimate of the measurement agreement range is -0.51 to + 0.53 ppm for CO 2 , -0.09 ‰ to + 0.07 ‰ for δ13 C, -0.50 ‰ to + 0.58 ‰ for δ18 O, -4.86 to + 6.16 ppb for CH 4 , -0.75 to + 1.20 ppb for N 2 O, and -0.14 to + 0.09 ppt for SF 6. A secondary approach of using the average of 2 standard deviations of the means for all flask samples taken in each individual sampling episode provided similar results. These upper and lower limits represent our best estimate of the measurement agreement at the 95 % confidence level for these individual laboratories, providing more confidence for using these datasets in various scientific applications (e.g., long-term trend analysis). [ABSTRACT FROM AUTHOR]