Diagnostic accuracy of the Panbio COVID-19 antigen rapid test device for SARS-CoV-2 detection in Kenya, 2021: A field evaluation.
Document Type
Article
Source
PLoS ONE. 1/25/2023, Vol. 17 Issue 1, p1-15. 15p.
Subject
*COVID-19 testing
*ANTIGEN analysis
*HEALTH facilities
*COVID-19
*COVID-19 pandemic
*RECEIVER operating characteristic curves
Language
ISSN
1932-6203
Abstract
Background: Accurate and timely diagnosis is essential in limiting the spread of SARS-CoV-2 infection. The reference standard, rRT-PCR, requires specialized laboratories, costly reagents, and a long turnaround time. Antigen RDTs provide a feasible alternative to rRT-PCR since they are quick, relatively inexpensive, and do not require a laboratory. The WHO requires that Ag RDTs have a sensitivity ≥80% and specificity ≥97%. Methods: This evaluation was conducted at 11 health facilities in Kenya between March and July 2021. We enrolled persons of any age with respiratory symptoms and asymptomatic contacts of confirmed COVID-19 cases. We collected demographic and clinical information and two nasopharyngeal specimens from each participant for Ag RDT testing and rRT-PCR. We calculated the diagnostic performance of the Panbio™ Ag RDT against the US Centers for Disease Control and Prevention's (CDC) rRT-PCR test. Results: We evaluated the Ag RDT in 2,245 individuals where 551 (24.5%, 95% CI: 22.8–26.3%) tested positive by rRT-PCR. Overall sensitivity of the Ag RDT was 46.6% (95% CI: 42.4–50.9%), specificity 98.5% (95% CI: 97.8–99.0%), PPV 90.8% (95% CI: 86.8–93.9%) and NPV 85.0% (95% CI: 83.4–86.6%). Among symptomatic individuals, sensitivity was 60.6% (95% CI: 54.3–66.7%) and specificity was 98.1% (95% CI: 96.7–99.0%). Among asymptomatic individuals, sensitivity was 34.7% (95% CI 29.3–40.4%) and specificity was 98.7% (95% CI: 97.8–99.3%). In persons with onset of symptoms <5 days (594/876, 67.8%), sensitivity was 67.1% (95% CI: 59.2–74.3%), and 53.3% (95% CI: 40.0–66.3%) among those with onset of symptoms >7 days (157/876, 17.9%). The highest sensitivity was 87.0% (95% CI: 80.9–91.8%) in symptomatic individuals with cycle threshold (Ct) values ≤30. Conclusion: The overall sensitivity and NPV of the Panbio™ Ag RDT were much lower than expected. The specificity of the Ag RDT was high and satisfactory; therefore, a positive result may not require confirmation by rRT-PCR. The kit may be useful as a rapid screening tool only for symptomatic patients in high-risk settings with limited access to rRT-PCR. A negative result should be interpreted based on clinical and epidemiological information and may require retesting by rRT-PCR. [ABSTRACT FROM AUTHOR]