Quantification of glucose-6-phosphate dehydrogenase activity by spectrophotometry: A systematic review and meta-analysis.
Document Type
Article
Source
PLoS Medicine. 5/14/2020, Vol. 17 Issue 5, p1-18. 18p. 4 Charts, 4 Graphs.
Subject
*GLUCOSE-6-phosphate dehydrogenase
*GLUCOSE-6-phosphate dehydrogenase deficiency
*META-analysis
*POINT-of-care testing
*PLASMODIUM vivax
*DEFINITIONS
Language
ISSN
1549-1277
Abstract
Background: The radical cure of Plasmodium vivax and P. ovale requires treatment with primaquine or tafenoquine to clear dormant liver stages. Either drug can induce haemolysis in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency, necessitating screening. The reference diagnostic method for G6PD activity is ultraviolet (UV) spectrophotometry; however, a universal G6PD activity threshold above which these drugs can be safely administered is not yet defined. Our study aimed to quantify assay-based variation in G6PD spectrophotometry and to explore the diagnostic implications of applying a universal threshold. Methods and findings: Individual-level data were pooled from studies that used G6PD spectrophotometry. Studies were identified via PubMed search (25 April 2018) and unpublished contributions from contacted authors (PROSPERO: CRD42019121414). Studies were excluded if they assessed only individuals with known haematological conditions, were family studies, or had insufficient details. Studies of malaria patients were included but analysed separately. Included studies were assessed for risk of bias using an adapted form of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Repeatability and intra- and interlaboratory variability in G6PD activity measurements were compared between studies and pooled across the dataset. A universal threshold for G6PD deficiency was derived, and its diagnostic performance was compared to site-specific thresholds. Study participants (n = 15,811) were aged between 0 and 86 years, and 44.4% (7,083) were women. Median (range) activity of G6PD normal (G6PDn) control samples was 10.0 U/g Hb (6.3–14.0) for the Trinity assay and 8.3 U/g Hb (6.8–15.6) for the Randox assay. G6PD activity distributions varied significantly between studies. For the 13 studies that used the Trinity assay, the adjusted male median (AMM; a standardised metric of 100% G6PD activity) varied from 5.7 to 12.6 U/g Hb (p < 0.001). Assay precision varied between laboratories, as assessed by variance in control measurements (from 0.1 to 1.5 U/g Hb; p < 0.001) and study-wise mean coefficient of variation (CV) of replicate measures (from 1.6% to 14.9%; p < 0.001). A universal threshold of 100% G6PD activity was defined as 9.4 U/g Hb, yielding diagnostic thresholds of 6.6 U/g Hb (70% activity) and 2.8 U/g Hb (30% activity). These thresholds diagnosed individuals with less than 30% G6PD activity with study-wise sensitivity from 89% (95% CI: 81%–94%) to 100% (95% CI: 96%–100%) and specificity from 96% (95% CI: 89%–99%) to 100% (100%–100%). However, when considering intermediate deficiency (<70% G6PD activity), sensitivity fell to a minimum of 64% (95% CI: 52%–75%) and specificity to 35% (95% CI: 24%–46%). Our ability to identify underlying factors associated with study-level heterogeneity was limited by the lack of availability of covariate data and diverse study contexts and methodologies. Conclusions: Our findings indicate that there is substantial variation in G6PD measurements by spectrophotometry between sites. This is likely due to variability in laboratory methods, with possible contribution of unmeasured population factors. While an assay-specific, universal quantitative threshold offers robust diagnosis at the 30% level, inter-study variability impedes performance of universal thresholds at the 70% level. Caution is advised in comparing findings based on absolute G6PD activity measurements across studies. Novel handheld quantitative G6PD diagnostics may allow greater standardisation in the future. Daniel Pfeffer and coauthors report on the assessment of glucose-6-phosphate dehydrogenase activity, which is required for safe use of some malaria treatments. Author summary: Why was this study done?: Complete cure of vivax malaria, the most geographically widespread malaria species, requires the use of 8-aminoquinoline drugs to clear dormant liver stages of the parasite ('radical cure'); however, these drugs can cause severe haemolysis in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Ultraviolet (UV) spectrophotometry is used as the reference test to measure G6PD activity, for validating new point-of-care diagnostics, and to determine population-specific definitions of G6PD deficiency. Currently, there is no universal threshold to define G6PD deficiency, and each laboratory must invest time and resources to derive site- and laboratory-specific definitions of G6PD deficiency. What did the researchers do and find?: We pooled measurements of G6PD activity from studies conducted across different countries and laboratories worldwide. We assessed the comparability of spectrophotometry results between these laboratories to see whether a universal definition and diagnostic cutoff for G6PD deficiency could be determined. There was substantial variation in the performance and absolute measurements of spectrophotometry conducted in different laboratories, hindering the definition of a universal cutoff for G6PD deficiency. What do these findings mean?: These findings highlight the importance of quality-control measures to minimise the influence of laboratory procedures on observed measurements. The data suggest that while a robust universal, assay-specific G6PD activity cutoff value can be established for diagnosis of severe G6PD deficiency (<30% normal enzyme activity), this approach is less robust for diagnosing intermediate G6PD deficiency. Newly developed diagnostic assays that are less sensitive to laboratory conditions and require less sample preparation are required and may help provide more standardised quantitative G6PD activity measurements across different contexts. [ABSTRACT FROM AUTHOR]