학술논문

Aspergillus fumigatus and mesophilic moulds in air in the surrounding environment downwind of non-hazardous waste landfill sites.
Document Type
Journal Article
Source
International Journal of Hygiene & Environmental Health. May2016, Vol. 219 Issue 3, p239-251. 13p.
Subject
*ASPERGILLUS fumigatus
*LANDFILL management
*METEOROLOGY
*PLANT species
*WASTE management
*AIR microbiology
*AIR pollution
*COMPARATIVE studies
*ENVIRONMENTAL monitoring
*FUNGI
*RESEARCH methodology
*MEDICAL cooperation
*RESEARCH
*WEATHER
*EVALUATION research
Language
ISSN
1438-4639
Abstract
Non-hazardous waste landfilling has the potential to release biological agents into the air, notably mould spores. Some species, such as Aspergillus fumigatus, may be a cause of concern for at-risk nearby residents. However, air concentration in the surrounding environment of non-hazardous waste landfill sites is poorly documented. An extensive sampling programme was designed to investigate the relationship between culturable mesophilic moulds and A. fumigatus concentrations in air and distance downwind of non-hazardous waste landfill sites. On-site and off-site repeated measurements were performed at four landfill sites during cold and warm seasons. A high-flow air-sampler device was selected so as to allow peak concentration measurement. Linear mixed-effects models were used to explain variability in the concentrations in air over time and across sites, seasons, instantaneous meteorological conditions and discharged waste tonnage. Concentrations of mesophilic moulds and A. fumigatus at off-site upwind sampling locations were compared with concentrations at each of the downwind sampling locations. At the tipping face location, peak concentration reached 480,000CFUm(-3) for mesophilic moulds and 9300CFUm(-3) for A. fumigatus. Compared with upwind background levels, these concentrations were, on average, approximately 20 and 40 times higher respectively. A steep decline in the concentration of both mesophilic moulds and A. fumigatus was observed between the tipping face location and the downwind property boundary (reduction by 77% and 84% respectively), followed by a low decline leading to a 90% and 94% reduction in concentration at 200m from the property boundary and beyond. With the 200m and 500m downwind sampling point values added together, the 97.5th percentile of concentration was 6013CFUm(-3) and 87CFUm(-3) for mesophilic moulds and A. fumigatus, respectively. Other determining factors were the discharged waste tonnage, the season, instantaneous temperature and wind velocity for mesophilic mould, and instantaneous temperature for A. fumigatus. At 200m and 500 downwind from the property boundary, mesophilic moulds and A. fumigatus concentrations were still higher than the local background level. However, whilst statistically significant, this increase does not suggest an excess risk to nearby residents' health when compared with the wide range of outdoor background levels reported in literature. These findings suggest that moulds and A. fumigatus may be transported beyond 200m from the property boundary in concentrations above those found locally upwind of the landfill site. Nevertheless, for exposure assessment purposes, comparison should also be made with background levels in wider areas which are either residential or through which people travel to work for example. [ABSTRACT FROM AUTHOR]