학술논문

242-A Campaign 94-1 post run document
Document Type
Technical Report
Author
Source
Other Information: PBD: 30 Sep 1994
Subject
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES HANFORD RESERVATION
RADIOACTIVE WASTE PROCESSING
EVAPORATORS
PERFORMANCE
CONSTRAINTS
SLURRIES
EVAPORATION
PRESSURE GRADIENTS
RECOMMENDATIONS
EXPERIMENTAL DATA 052001
WASTE PROCESSING
Language
English
Abstract
The purpose of this post-run document is to summarize the results of 242-A Evaporator Campaign 94-1 as required. Campaign 94-1 represents the first Evaporator operation since 1989, following completion of the B-534 upgrades and Liquid Effluent Retention Facility (LERF) construction. The purpose of Campaign 94-1 was to concentrate dilute waste from TK-102-AW, TK-106-AW, and TK-103-AP. From an available 2.87 million gallon feedstock of dilute waste contained in 102-AW, 106-AW and 103-AP, an overall Waste Volume Reduction (WVR) of 2.39 million gallons (83% WVRF) was achieved. At the completion of the campaign, approximately 477,000 gallons of dilute double-shell slurry feed (DDSSF) was produced with a SpG. of 1.25--1.30. Total process condensate discharged to LERF was 3.09 million gallons, achieving a condensate/WVR ratio of 1.29. Throughput for Campaign 94-1 was 5.27 million gallons. Total steam condensate and cooling water discharge to B-pond was 4.7 and 216 million gallons respectively. The evaporator operated approximately 43 days of the 60 day campaign for a total operating efficiency of 73%. Campaign 94-1 was completed without any discharge limit, Operating Specification Document, or Operational Safety Requirement violations. Major problems encountered during the run included the following: (1) high CA1 deentrainment pad dP`s caused by foaming, (2) condensate pump P-C100 failure, and (3) ion exchange column dP`s and efficiency.