학술논문

Principais carbonilas no ar de locais públicos no Rio de Janeiro
Document Type
article
Source
Química Nova. January 2008 31(2)
Subject
formaldehyde
indoor
air pollution
Language
Portuguese
ISSN
0100-4042
Abstract
An air quality evaluation of indoor environments with focus on lower carbonyls was carried out in 50 public places using TO-11A methodology. Formaldehyde levels (ranging from 12.5 to 1034 mg m-3) were above the threshold limit in 49 of 50 analyzed samples while acetaldehyde (ranging from 5.2 to 840 mg m-3) and acetone (ranging from 5.5 to 4839 mg m-3) were respectively bellow the limits of OSHA and NIOSH in all samples. However all samples were bellow the threshold limits suggested by the Brazilian legislation - NR-15. A correlation study between the carbonyls and temperature and humidity was also done.