학술논문

Influence of Abutment Collar Height and Implant Length on Stress Distribution in Single Crowns
Document Type
article
Source
Brazilian Dental Journal. June 2019 30(3)
Subject
dental implants
prosthetic abutments, finite element analysis, single dental implants, anterior single crowns
Language
English
ISSN
0103-6440
Abstract
This in silico study evaluated the influence of the abutment collar height and implants length on the biomechanical behavior of morse taper single dental implants with different crown-to-implant ratio. Six virtual models were constructed (S11, M11, L11, S13, M13 and L13) by combining short (S: 2.5 mm), medium (M: 3.5 mm) or long (L: 4.5 mm) abutment collar heights with different implant lengths (11 or 13-mm). An upper central incisor of 11-mm height was constructed on top of each abutment. Each set was positioned in a virtual bone model and exported to analyze mathematically. A 0.60-mm mesh was created after convergence analysis and a 49 N load was applied to the cingulum of the crown at an angle of 45°. Load-generated stress distribution was analyzed in the prosthetic components according to von Mises stress criteria (σvM) and in the cortical and cancellous bone by means of shear stress (εmax). The use of longer collar abutments (L11) increased the stress on the abutment by 250% and resulted in 40% higher stresses on the screw and 92% higher cortical shear stresses compared to short collared abutments (S11). Increasing the implant length produced a slight stress reduction on cortical bone. Cancellous bone was not affected by the crown-to-implant ratio. Longer abutment collars concentrate stresses at the implant level and cortical bone by increasing the crown-to-implant ratio.