학술논문

CT-monitored minimal ablative margin control in single-session microwave ablation of liver tumors: an effective strategy for local tumor control
Document Type
article
Source
European Radiology. 32(9)
Subject
Biomedical and Clinical Sciences
Clinical Sciences
Oncology and Carcinogenesis
Liver Disease
Liver Cancer
Digestive Diseases
Rare Diseases
Cancer
Biomedical Imaging
Carcinoma
Hepatocellular
Catheter Ablation
Humans
Liver Neoplasms
Margins of Excision
Microwaves
Retrospective Studies
Tomography
X-Ray Computed
Treatment Outcome
Ablation techniques
Computed tomography
X-ray
Liver neoplasms
Nuclear Medicine & Medical Imaging
Clinical sciences
Language
Abstract
ObjectivesTo investigate the usefulness of minimal ablative margin (MAM) control by intra-procedural contrast-enhanced CT (CECT) in microwave ablation (MWA) of liver tumors.MethodsA total of 334 consecutive liver tumors (240 hepatocellular carcinomas [HCCs] and 94 colorectal liver metastases [CRLMs]) in 172 patients treated with percutaneous MWA were retrospectively included. MAM of each tumor was assessed after expected ablation completion using intra-procedural CECT, allowing within-session additional ablation to any potentially insufficient margin. On immediate post-MWA MRI, complete ablation coverage of tumor and final MAM status were determined. The cumulative local tumor progression (LTP) rate was estimated by using the Kaplan-Meier method. To identify predictors of LTP, Cox regression analysis with a shared frailty model was performed.ResultsIntra-procedural CECT findings prompted additional ablation in 18.9% (63/334) of tumors. Final complete ablation coverage of tumor and sufficient MAM were determined by MRI to be achieved in 99.4% (332/334) and 77.5% (259/334), and their estimated 6-month, 1-year, and 2-year LTP rates were 3.2%, 7.5%, and 12.9%; and 1.0%, 2.1%, and 6.9%, respectively. Insufficient MAM on post-MWA MRI, perivascular tumor location, and tumor size (cm) were independent risk factors for LTP (hazard ratio = 14.4, 6.0, and 1.1, p < 0.001, p = 0.003, and p = 0.011, respectively), while subcapsular location and histology (HCC vs CRLM) were not.ConclusionsIn MWA of liver tumors, intra-procedural CECT monitoring of minimal ablative margin facilitates identification of potentially suboptimal margins and guides immediate additional intra-session ablation to maximize rates of margin-sufficient ablations, the latter being a highly predictive marker for excellent long-term local tumor control.Key points• In MWA of liver tumors, intra-procedural CECT can identify potentially suboptimal minimal ablative margin, leading to immediate additional ablation in a single treatment session. • Achieving a finally sufficient ablative margin through the MWA with intra-procedural CECT monitoring of minimal ablative margin results in excellent local tumor control.