학술논문

Optimal Threshold of Controlled Attenuation Parameter for Detection of HIV-Associated NAFLD With Magnetic Resonance Imaging as the Reference Standard
Document Type
article
Source
Clinical Infectious Diseases. 72(12)
Subject
Biomedical and Clinical Sciences
Clinical Sciences
Liver Disease
Chronic Liver Disease and Cirrhosis
Prevention
HIV/AIDS
Biomedical Imaging
Infectious Diseases
Hepatitis
Digestive Diseases
4.1 Discovery and preclinical testing of markers and technologies
Detection
screening and diagnosis
Inflammatory and immune system
Infection
Good Health and Well Being
Biopsy
Elasticity Imaging Techniques
Female
HIV Infections
Humans
Liver
Magnetic Resonance Imaging
Male
Non-alcoholic Fatty Liver Disease
Prospective Studies
ROC Curve
Reference Standards
NASH
steatosis
MRI-PDFF
Biological Sciences
Medical and Health Sciences
Microbiology
Clinical sciences
Language
Abstract
BackgroundControlled attenuation parameter (CAP) is an ultrasound-based point-of-care method to quantify liver fat; however, the optimal threshold for CAP to detect pathologic liver fat among persons living with human immunodeficiency virus (HIV; PLWH) is unknown. Therefore, we aimed to identify the diagnostic accuracy and optimal threshold of CAP for the detection of liver-fat among PLWH with magnetic resonance imaging proton-density fat fraction (MRI-PDFF) as the reference standard.MethodsPatients from a prospective single-center cohort of PLWH at risk for HIV-associated nonalcoholic fatty liver disease (NAFLD) who underwent contemporaneous MRI-PDFF and CAP assessment were included. Subjects with other forms of liver disease including viral hepatitis and excessive alcohol intake were excluded. Receiver operatic characteristic (ROC) curve analysis were performed to identify the optimal threshold for the detection of HIV-associated NAFLD (liver fat ≥ 5%).ResultsSeventy PLWH (90% men) at risk for NAFLD were included. The mean (± standard deviation) age and body mass index were 48.6 (±10.2) years and 30 (± 5.3) kg/m2, respectively. The prevalence of HIV-associated NAFLD (MRI-PDFF ≥ 5%) was 80%. The M and XL probes were used for 56% and 44% of patients, respectively. The area under the ROC curve of CAP for the detection of MRI-PDFF ≥ 5% was 0.82 (0.69-0.95) at the cut-point of 285 dB/m. The positive predictive value of CAP ≥ 285 dB/m was 93.2% in this cohort with sensitivity of 73% and specificity of 78.6%.ConclusionsThe optimal cut-point of CAP to correctly identify HIV-associated NAFLD was 285 dB/m, is similar to previously published cut-point for primary NAFLD and may be incorporated into routine care to identify patients at risk of HIV-associated NAFLD.