Examining lung mechanical strains as influenced by breathing volumes and rates using experimental digital image correlation
Document Type
article
Source
Respiratory Research. 23(1)
Subject
Acute Respiratory Distress Syndrome
Rare Diseases
Bioengineering
Lung
Respiratory
Animals
High-Frequency Ventilation
Humans
Respiration
Respiration
Artificial
Swine
Tidal Volume
Digital image correlation
Topological strain
Pulmonary mechanics
Anisotropy
Heterogeneity
Biomechanics
Ventilation
Inflation
Cardiorespiratory Medicine and Haematology
Clinical Sciences
Respiratory System
Language
Abstract
BackgroundMechanical ventilation is often employed to facilitate breathing in patients suffering from respiratory illnesses and disabilities. Despite the benefits, there are risks associated with ventilator-induced lung injuries and death, driving investigations for alternative ventilation techniques to improve mechanical ventilation, such as multi-oscillatory and high-frequency ventilation; however, few studies have evaluated fundamental lung mechanical local deformations under variable loading.MethodsPorcine whole lung samples were analyzed using a novel application of digital image correlation interfaced with an electromechanical ventilation system to associate the local behavior to the global volume and pressure loading in response to various inflation volumes and breathing rates. Strains, anisotropy, tissue compliance, and the evolutionary response of the inflating lung were analyzed.ResultsExperiments demonstrated a direct and near one-to-one linear relationship between applied lung volumes and resulting local mean strain, and a nonlinear relationship between lung pressures and strains. As the applied air delivery volume was doubled, the tissue surface mean strains approximately increased from 20 to 40%, and average maximum strains measured 70-110%. The tissue strain anisotropic ratio ranged from 0.81 to 0.86 and decreased with greater inflation volumes. Local tissue compliance during the inflation cycle, associating evolutionary strains in response to inflation pressures, was also quantified.ConclusionVentilation frequencies were not found to influence the local stretch response. Strain measures significantly increased and the anisotropic ratio decreased between the smallest and greatest tidal volumes. Tissue compliance did not exhibit a unifying trend. The insights provided by the real-time continuous measures, and the kinetics to kinematics pulmonary linkage established by this study offers valuable characterizations for computational models and establishes a framework for future studies to compare healthy and diseased lung mechanics to further consider alternatives for effective ventilation strategies.