A Normal Capillary Refill Time of ≤ 2 Seconds is Associated with Superior Vena Cava Oxygen Saturations of ≥ 70%
Document Type
Academic Journal
Source
The Journal of Pediatrics. Jun 01, 2011 158(6):968-972
Subject
Language
English
ISSN
0022-3476
Abstract
OBJECTIVE: To test the hypothesis that a normal capillary refill time (CRT) ≤ 2 seconds is associated with superior vena cava oxygen saturation (ScvO2) ≥ 70% in critically ill children. STUDY DESIGN: Two-year, prospective study in a tertiary-level pediatric intensive care unit. Whenever ScvO2 measurements were obtained, central (forehead/sternum) and peripheral (finger/toe) CRTs were concomitantly assessed. RESULTS: Central and peripheral CRTs ≤ 2 seconds were both associated with ScvO2 ≥ 70% (P < .01). Sensitivity/specificity analyses revealed that central CRT ≤ 2 seconds demonstrated a sensitivity of 84.4%, specificity of 71.4%, positive predictive value of 93.1%, and negative predictive value of 50.0% in predicting ScvO2 ≥ 70%. Peripheral CRT ≤ 2 seconds had a sensitivity of 71.9%, specificity of 85.7%, positive predictive value of 95.8%, and negative predictive value of 40.0% in predicting ScvO2 ≥ 70%. CONCLUSIONS: A normal CRT ≤ 2 seconds can be predictive of ScvO2 ≥ 70%. Our study corroborates the recommendations of the Pediatric Advanced Life Support curricula targeting a normal CRT ≤ 2 seconds as a therapeutic endpoint for goal-directed shock resuscitation. This clinical target remains particularly relevant in community hospitals when the ability to obtain central venous catheter access may be limited and ScvO2 data unavailable.