학술논문

The national colonoscopy audit: a nationwide assessment of the quality and safety of colonoscopy in the UK
Document Type
Academic Journal
Source
Gut. Feb 01, 2013 62(2):242-249
Subject
Language
English
ISSN
0017-5749
Abstract
OBJECTIVE: To perform a comprehensive audit of all colonoscopy undertaken in the UK over a 2-week period. DESIGN: Multi-centre survey. All adult (≥16 years of age) colonoscopies that took place in participating National Health Service hospitals between 28 February 2011 and 11 March 2011 were included. RESULTS: Data on 20 085 colonoscopies and 2681 colonoscopists were collected from 302 units. A validation exercise indicated that data were collected on over 94% of all procedures performed nationally. The unadjusted caecal intubation rate (CIR) was 92.3%. When adjusted for impassable strictures and poor bowel preparation the CIR was 95.8%. The polyp detection rate was 32.1%. The polyp detection rate for larger polyps (≥10mm diameter) was 11.7%. 92.3% of resected polyps were retrieved. 90.2% of procedures achieved acceptable levels of patient comfort. A total of eight perforations and 52 significant haemorrhages were reported. Eight patients underwent surgery as a consequence of a complication. CONCLUSIONS: This is the first national audit of colonoscopy that has successfully captured the majority of adult colonoscopies performed across an entire nation during a defined time period. The data confirm that there has been a significant improvement in the performance of colonoscopy in the UK since the last study reported seven years ago (CIR 76.9%) and that performance is above the required national standards.