학술논문

증기발생기 전열관 2차측 응력부식균열의 실험실적 모사 방법
Laboratorial technique for fabrication of outer diameter stress corrosion cracking on steam generator tubing
Document Type
Article
Source
Corrosion Science and Technology. Jun 30, 2014 13(3):112
Subject
direct current potential drop method
eddy current test
non-through wall crack
steam generator tubing
stress corrosion cracking
through wall crack
Language
English
ISSN
1598-6462
Abstract
In this work, it is aimed to develop the fabrication method of axial stress corrosion cracking (SCC) defects having various sizes, on the outer diameter surface of the steam generator (SG) tubings. To control the length of the artificial SCC defect, the specific area of the SG tubing samples was exposed to an acidic solution after a sensitization heat treatment. During the exposure to an acidic solution, a direct current potential drop (DCPD) method was adopted to monitor the crack depth. The size of the SCC defect was first evaluated by an eddy current test (ECT), and then confirmed by a destructive examination. From the comparison, it was found that the actual crack length was well controlled to be similar to the length of the surface exposed to an acidic solution (5, 10, 20 or 30 mm in this work) with small standard deviation. From in-situ monitoring of the crack depth using the DCPD method, it was possible to distinguish a non-through wall crack from a through wall crack, even though the depth of the non-through wall crack was not able to be precisely controlled. The fabrication method established in this work was useful to simulate the SCC defect having similar size and ECT signals as compared to the field cracks in the SG tubings of the operating Korean PWRs.