학술논문

Voltage balance strategy for DC‑port failures of three‑phase cascaded H‑bridge rectifiers based on negative sequence current injection
Document Type
Article
Source
Journal of Power Electronics, 22(8), pp.1242-1254 Aug, 2022
Subject
전기공학
Language
English
ISSN
2093-4718
1598-2092
Abstract
The three-phase cascaded H-bridge rectifier (CHBR) is widely used in high power and high voltage applications. This paper focuses on the load removed from the DC port of a three-phase CHBR, which can cause single-phase DC-port voltage unbalance issues and three-phases DC-port voltage unbalance issues. This paper proposes a voltage balance control strategy based on negative sequence current injection for three-phase CHBR to deal with the unbalance problem. An individual DC-port voltage control strategy is designed to balance the DC-port voltage in the faulty phase. In addition, a negative sequence current injection control strategy is responsible for balancing the DC-port voltages in the three phase CHBR. The effectiveness and feasibility of the proposed voltage control strategy based on negative sequence current injection is verified by the experimental results.