학술논문

Development of -1MV Surge Absorber Systems for ITER NBI / ITER NBI用-1MV短絡時におけるサージ吸収システムの開発
Document Type
Journal Article
Source
電気学会論文誌B(電力・エネルギー部門誌) / IEEJ Transactions on Power and Energy. 2019, 139(9):576
Subject
DC
FINEMET
ITER
NBI
high voltage
surge absorber
サージアブゾーバ
ファインメット
直流
高電圧
Language
Japanese
ISSN
0385-4213
1348-8147
Abstract
This paper presents the development results of surge absorber system for an ITER neutral beam injector. Circuit design and insulation design were carried out to withstand 200 times breakdown at beam source. Circuit analysis considering the B-H characteristics of FINEMET core for surge absorption shows the decrease in surge current by 60% due to the developed system. The validity of the established design was demonstrated by the actual-product tests for Transmission Line 2; FINEMET core satisfied the required saturation characteristics of 0.7Vs, and also withstood the impulse voltage of 200kV loaded in the axial direction at the reduced pressure condition of 0.1MPa,abs in the SF6 gas atmosphere.