학술논문

Capacitor Current Imbalance and Its Suppression Method Between Phase Legs for Three-phase Inverter / 三相インバータのレグ間キャパシタ電流アンバランスとその抑制法
Document Type
Journal Article
Source
電気学会論文誌D(産業応用部門誌) / IEEJ Transactions on Industry Applications. 2018, 138(6):491
Subject
DC-link capacitor
DCキャパシタ
current imbalance
resonance
stray inductance
switching frequency
スイッチング周波数
共振
寄生インダクタンス
電流アンバランス
Language
Japanese
ISSN
0913-6339
1348-8163
Abstract
This paper proposes a method to suppress the capacitor current imbalance between the phase legs of a three-phase inverter circuit. This circuit consists of half-bridge modules and DC-link capacitors closely connected to each module. It can be designed for low stray inductance between power semiconductor devices and DC-link capacitors in each module. However, in the conventional structure, the stray inductance between the phase legs may lead to an imbalance in the capacitor current due to the DC-side resonance phenomenon under a higher switching frequency condition by using a SiC MOSFET. This paper presents the analyses of the equivalent circuit considering the circuit configuration, which suggests that capacitor current imbalance occurs depending on the stray inductance between phase legs. To suppress the capacitor current imbalance, a delta-type bus bar connecting phase legs is proposed. The experiment results at 300V and 4.6A demonstrate the suppression effectiveness of the proposed method.