학술논문

ICONE23-1436 REAL-TIME PARTICLE VOLUME FRACTION MEASUREMENT IN CENTRIFUGES BY WIRELESS ELECTRICAL RESISTANCE DETECTOR
Document Type
Journal Article
Source
The Proceedings of the International Conference on Nuclear Engineering (ICONE). 2015, 1
Subject
Centrifuges; Wireless
Electrical resistance detector
Particle volume fraction
Real-time measurement
Language
English
ISSN
2424-2934
Abstract
In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated.

Online Access