학술논문

STUDY ON HYGROTHERMAL BEHAVIOR OF WALL ASSEMBLY WITH VENTED CAVITY IN CONSIDERATION OF DRIVING RAIN (PART1): IMPACT OF RAIN PENETRATION AND WATER ABSORPTION OF EXTERIOR SYSTEM ON HYGROTHERMAL BEHAVIOR WITHIN WALL ASSEMBLY / 雨掛かりを考慮した外壁通気構法の水分挙動に関する研究(その1):通気層への雨水浸入および外装材吸水が壁内湿度に及ぼす影響
Document Type
Journal Article
Source
日本建築学会環境系論文集 / Journal of Environmental Engineering (Transactions of AIJ). 2020, 85(767):19
Subject
Absorption and desorption
Concealed condensation in summer season
Field survey
Rain penetration
Siding
Vented cavity
サイディング
吸放湿
夏型結露
実測
通気層
雨水浸入
Language
Japanese
ISSN
1348-0685
1881-817X
Abstract
To unravel mechanism of the internal condensation due to moisture cause the rain water, lab-experiments and field measurements were conducted. In the lab-experiments, water penetration rate and water absorption coefficient of sidings were quantitated. In the field measurement, the internal condensation was reproduced by intermittent injection of rain water into the vented cavity. Additionally, the drying performance of different ventilation configurations were compared by humidity and moisture content variations within wall assemblies in field measurements. The findings of the study are as follows