학술논문

SEISMIC BEHAVIOR OF THE CONNECTING STRUCTURE IN HANEDA AIRPORT D-RUNWAY DURING THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE AND ITS REPONSE ANALYSIS USING FLIP / 羽田空港D滑走路埋立/桟橋接続部の3.11地震時の挙動とFLIPによる再現解析
Document Type
Journal Article
Source
土木学会論文集B3(海洋開発) / Journal of Japan Society of Civil Engineers, Ser. B3 (Ocean Engineering). 2021, 77(2)379
Subject
D-runway
FLIP
Haneda Airport
The 2011 off the Pacific coast of Tohoku earthquake
earthquake observation
seismic design
Language
Japanese
ISSN
2185-4688
Abstract
On March 11, 2011, the 2011 off the Pacific coast of Tohoku Earthquake occurred and strong motion records were obtained on the D-Runway of Haneda Airport. The behavior of the D-Runway during the earthquake was investigated using the observation records and the validity of its seismic design was verified. FLIP simulation was performed using the model and parameters used for the design of the connecting structure between the landfill and pier sections by inputting the observed ground acceleration. As a result, the response of the landfill and the pier simulated by FLIP were in good agreement with the observed records. Regarding the connection structure, although the lateral displacement obtained by FLIP exceeded the observed value, it was confirmed that the seismic design using FLIP resulted in a conservative design.