In Vitro Assessment of Dialysis Membrane as an Endotoxin Transfer Barrier: Geometry, Morphology, and Permeability
Document Type
Report
Source
Artificial Organs. Sept, 2008, Vol. 32 Issue 9, p701, 10 p.
Subject
Permeability -- Analysis
Language
English
ISSN
0160-564X
Abstract
To purchase or authenticate to the full-text of this article, please visit this link: http://dx.doi.org/10.1111/j.1525-1594.2008.00592.x Byline: Michael Henrie (*), Cheryl Ford (*), Marion Andersen (*), Eric Stroup (*), Jose Diaz-Buxo ([dagger]), Ben Madsen ([double dagger]), David Britt ([double dagger]), Chih-Hu Ho (*) Keywords: Endotoxin; Hemodialysis membranes; Geometry; Dialysis fluid; Inflammation; Back filtration Abstract: Abstract: High-flux dialysis membranes used with bicarbonate dialysis fluid increase the risk of back diffusion of bacterial endotoxin into the blood during hemodialysis. Endotoxin transfer of various synthetic fiber membranes was tested with bacterial culture filtrates using an in vitro system testing both diffusive and convective conditions. Membranes were tested in a simulated dialysis mode with endotoxin challenge material ([proportional to]420 EU/mL) added to the dialysis fluid, with saline used to model both blood and dialysis fluid. Samples were taken of both blood and dialysis fluid, and analyzed using a kinetic turbidimetric Limulus amoebocyte lysate assay. Endotoxin was found in all of the blood circuit samples, except for the Fresenius Optiflux F200NR.sup.e and thick-wall membranes. All membranes tested removed [proportional to]95% of the endotoxin from solution, with the residual [proportional to]5% recirculating within the dialysis fluid compartment. Endotoxin distribution through the fiber membrane was examined using a fluorescent-labeled endotoxin conjugate. Fluorescence images indicate that adsorption occurs throughout the membrane wall, with the greatest concentration of endotoxin located at the inner lumen. Contact angle analysis was able to show that all membranes exhibit a more hydrophilic lumen and a more hydrophobic outer surface except for the polyethersulfone membranes, which were of equal hydrophobicity. Resulting data indicate that fiber geometry plays an important role in the ability of the membrane to inhibit endotoxin transfer, and that both adsorption and filtration are methods by which endotoxin is retained and removed from the dialysis fluid circuit. Author Affiliation: (*)Dialyzer R&D Department, Fresenius Medical Care North America, Ogden, UT; ([dagger])Home Therapies Development, Fresenius Medical Care North America, Charlotte, NC; and ([double dagger])Biological Engineering Department, Utah State University, Logan, UT, USA Article History: Received May 2007; revised October 2007. Article note: Dr. Chih-Hu Ho, Dialyzer R&D Department, Fresenius Medical Care North America, 475 West 13th Street, Ogden, UT 84404, USA. E-mail: chih-hu.ho@fmc-na.com