학술논문
고온・고압 노내조사시험설비의 부동태 처리
Passivation for High Temperature and Pressure Irradiation Test Loop
Passivation for High Temperature and Pressure Irradiation Test Loop
Document Type
Article
Text
Text
Source
한국기계기술학회지, 12/31/2010, Vol. 12, Issue 4, p. 155-160
Subject
Language
Korean
ISSN
1229-604X
Abstract
Fuel test loop is an irradiation test facility which can conduct the irradiation tests of nuclear fuels and materials at HANARO. The FTL simulates the operating conditions of commercial nuclear power plants such as their pressure, temperature, flow and water chemistry to conduct the irradiation and thermo-hydraulic tests. The passivation of the fuel test loop was performed for the main cooling system in the commissioning stage with satisfaction of the operation criterion such as temperature and water chemistry conditions. The experimental results show that the passivation was completed successfully.