학술논문

전자제어 밸브(ECV) 내부로 유입되는 냉매의 유동 특성에 관한 연구
A Study on the Refrigerant Flow Characteristics Flowing into the Interior of the Electromagnetic Control Valve
Document Type
Article
Text
Source
한국기계기술학회지, 02/28/2014, Vol. 16, Issue 1, p. 1173-1178
Subject
Variable Displacement Compressor(가변 용량형 압축기)
Computational Fluid Dynamics(유동해석)
ECV((Electromagnetic control valve(전자제어 밸브)
Language
Korean
ISSN
1229-604X
Abstract
In this paper, we analyzed the characteristics of the mass flow rate and velocity of the refrigerant in response to a change in the number of holes and the diameter size(Type-1~4) of the valve guide refrigerant to flow from Pc to Ps when the pressure is constant. Type-1 is 40% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-2 is 64% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-3 is 50% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-4 is 47% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate.