학술논문

Passivity-Oriented Impedance Shaping for LCL-Filtered Grid-Connected Inverters
Document Type
Periodical
Source
IEEE Transactions on Industrial Electronics IEEE Trans. Ind. Electron. Industrial Electronics, IEEE Transactions on. 70(9):9078-9090 Sep, 2023
Subject
Power, Energy and Industry Applications
Signal Processing and Analysis
Communication, Networking and Broadcast Technologies
Impedance
Inverters
Power system stability
Low-pass filters
Band-pass filters
Stability criteria
Phase locked loops
Grid-connected inverter
impedance shaping
++%24LCL%24<%2Ftex-math>+<%2Finline-formula>+<%2Fnamed-content>+filter%22"> $LCL$ filter
passivity
stability
Language
ISSN
0278-0046
1557-9948
Abstract
The passivity theory provides an effective way to tackle the instability due to the inverter-grid interaction, which tells that the system stability can be guaranteed if the grid impedance and the inverter output impedance are both passive. Since the grid impedance is generally passive, the system stability can be immune to the grid impedance variation if the inverter output impedance is also passive. This article develops a series and parallel impedance shaping method to ensure that the output impedance of the LCL -filtered grid-connected inverter is dissipative up to the Nyquist frequency. Since the inverter output impedance can be decomposed into two passive elements and one active element, its nondissipative property results from the latter, and thus the virtual series impedance shaping is introduced to cancel out the active element. Unfortunately, it poses impact on the low-frequency loop gain and system phase margin in the meantime. To alleviate this impact, a high-pass filter is inserted in the series impedance shaping function. Subsequently, a virtual parallel impedance is introduced to enhance the passivity robustness, such as against filter parameter variations. Moreover, the proposed method does not require any additional sensors. Experiments from a 6-kW prototype confirm the effectiveness of the proposed method.