Dynamic Measurement Assessments of Sensory Gloves Based on Resistive Flex Sensors and Inertial Measurement Units
Document Type
Periodical
Source
IEEE Transactions on Instrumentation and Measurement IEEE Trans. Instrum. Meas. Instrumentation and Measurement, IEEE Transactions on. 72:1-10 2023
Subject
Power, Energy and Industry Applications
Components, Circuits, Devices and Systems
Calibration
Sensors
Light emitting diodes
Robot sensing systems
Thumb
Testing
Reliability
Inertial measurement unit (IMU)
motion measurements
resistive flex sensor (RFS)
sensory gloves
wearable electronics
Language
ISSN
0018-9456
1557-9662
Abstract
Sensory gloves are devices capable of measuring finger movements and are useful in numerous applications, many of which require real-time data acquisition. However, the procedures explored in the literature to assess measurement repeatability and reliability mainly rely on static or quasi-static conditions. To overcome this limitation, here we propose a testing procedure for assessing measurements under dynamic conditions (slow, medium, and rapid finger joint movements). To this aim, we used two sensory gloves, one based on resistive flex sensors (RFSs) and another based on inertial measurement units (IMUs)—as two of the most adopted types. Our study demonstrated the feasibility of measuring dynamic finger movements and the differences in dynamic measurement repeatability and reliability between RFS- and IMU-based gloves when considering the angles (in degrees) of each finger joint. The RFS-based glove scored with an average range ± standard deviation (SD) of 6.84° ± 2.77° and an intraclass correlation coefficient (ICC) of 0.77 ± 0.14, whereas the IMU-based glove scored with an average range of 8.49° ± 2.72° and an ICC of 0.75 ± 0.14. Both gloves exhibited better repeatability and reliability at the slowest speed, with the RFS-based glove having a higher repeatability than the IMU-based one ( $p < 0.001$ ). Moreover, when compared to previous studies, the results (in terms of reliability and repeatability) here obtained under dynamic conditions are comparable to those obtained under static or quasi-static conditions. In summary, our results indicate that both proposed sensory gloves are suitable for most applications that require dynamic interactions.