학술논문

The new read-out electronics for the BaF/sub 2/-calorimeter TAPS
Document Type
Conference
Source
2002 IEEE Nuclear Science Symposium Conference Record Nuclear science symposium Nuclear Science Symposium Conference Record, 2002 IEEE. 1:585-589 vol.1 2002
Subject
Nuclear Engineering
Power, Energy and Industry Applications
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Telephony
Solid scintillation detectors
Energy measurement
Spectroscopy
Collaboration
Pulse measurements
Analog-digital conversion
Delay
Scintillation counters
Testing
Language
Abstract
A highly compact and fast VME based read-out board for BaF/sub 2/ scintillation detectors has been designed, developed and finally tested in an in-beam experiment. Adapted to the excellent properties of BaF/sub 2/, the unit allows to digitize time, energy and pulse-shape information of 4 detector channels in parallel. The board is piggy-back plugged onto a motherboard containing a high-speed 12-bit ADC and the VME interface, commercially available in the customized version CAEN V874A. Both together combine to one single VME slot. A first measurement of the photon response of a TAPS sub-array with energy marked photons up to 2.6 GeV has documented the full functionality and excellent performance.