Measurements and performance of a low noise 64-channel ASIC with CdTe strip detectors
Document Type
Conference
Source
IEEE Nuclear Science Symposuim & Medical Imaging Conference Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE. :1560-1564 Oct, 2010
Subject
Nuclear Engineering
Engineered Materials, Dielectrics and Plasmas
Bioengineering
Power, Energy and Industry Applications
Components, Circuits, Devices and Systems
Computing and Processing
Communication, Networking and Broadcast Technologies
Detectors
Application specific integrated circuits
Leakage current
Noise
Silicon
Current measurement
Electron tubes
Language
ISSN
1082-3654
Abstract
We present the design and measurement results of an ASIC aimed to work with both AC and DC coupled detectors, in a single photon counting mode with an energy window. The ASIC can work with input leakage currents in the range from −10 nA up to 7 nA. The ENC obtained with an AC-coupled Si detector is 120 e − for a peaking time T p = 115 ns and C det = 1.2 pF. With a DC-coupled CdTe detector, the ENC is 160 e − rms for a peaking time T p = 380 ns and C det = 2 pF and the leakage current I dleak = 0.15 nA. The implemented trim DACs at the discriminator inputs allows to minimize the effective threshold spread to 8 e − rms (at one sigma level). We also present the updated version of the ASIC that can operate with X-ray energies up to 100 keV and has an improved high count rate performance. For the new ASIC the preliminary measurements with the CdTe detector are presented.