학술논문

Multiple Module Pixellated CdTe Spectroscopic X-Ray Detector
Document Type
Periodical
Source
IEEE Transactions on Nuclear Science IEEE Trans. Nucl. Sci. Nuclear Science, IEEE Transactions on. 60(2):1197-1200 Apr, 2013
Subject
Nuclear Engineering
Bioengineering
Detectors
Application specific integrated circuits
Arrays
Data acquisition
Image edge detection
Imaging
Image quality
CdTe
CdZnTe
imaging
spectroscopic
X-ray detector
Language
ISSN
0018-9499
1558-1578
Abstract
A pixellated CdTe detector system comprising 2x2 detector modules has been developed for high energy spectroscopic X-ray imaging applications and has an active area of 16 cm$^{2}$ . The detector modules are made from the HEXITEC 80x80 ASIC and 1 mm thick CdTe with Al-Schottky contacts. The CdTe has 250 $\mu$m pitch pixels with an outer guard ring on the same pitch. The single HEXITEC 80x80 detectors have an average energy resolution (FWHM) of 800 eV at 59.9 keV. Limitations in the multiple module DAQ system mean that the energy resolution of the pixels in the 2x2 detector array is 2.0 keV at 59.9 keV. The spacing between the tiled detector modules is 150 $\mu$ m which results in an inactive area equivalent to 3 pixels, including the guard ring on the edge of the detectors. The modular detector configuration demonstrates the potential to create large area detector arrays in the future.