학술논문

Wideband Vector Corrected Measurements on a Modified Vector Network Analyzer (VNA) System
Document Type
Conference
Source
2022 99th ARFTG Microwave Measurement Conference (ARFTG) ARFTG Microwave Measurement Conference (ARFTG), 2022 99th. :1-4 Jun, 2022
Subject
Components, Circuits, Devices and Systems
Engineered Materials, Dielectrics and Plasmas
Fields, Waves and Electromagnetics
Microwave measurement
Radio frequency
Impedance measurement
Network analyzers
Switches
Dynamic range
Calibration
Wideband calibration
wideband measurement
vector network analyzer measurement
measurement technique
Language
Abstract
Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.