학술논문

The Spear 3 Diagnostic Beamlines
Document Type
Conference
Source
Proceedings of the 2005 Particle Accelerator Conference Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the. :4057-4059 2005
Subject
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Nuclear Engineering
Robotics and Control Systems
Cameras
Optical beams
Optical interferometry
Optical refraction
X-ray imaging
Diffraction
Phosphors
Electron optics
Synchrotron radiation
Pulse measurements
Language
ISSN
1944-4680
2152-9582
Abstract
SPEAR 3 has two diagnostic beam lines: an x-ray pinhole camera and a visible/UV laboratory. The pinhole camera images ∼ 8 keV dipole radiation on a phosphor screen with a remote computer to capture digital images and a parallel video signal to the control room. The visible/UV beam line features an 8 mm high GlidCop ‘cold finger’ to remove the x-ray core of the beam. The remaining light is deflected horizontally onto an optical bench where it is focused via reflective (Cassegrain) or refractive optics. The visible beam can be split into branch lines for a variety of experimental applications. This paper describes the experimental set up and projected use of both systems.