학술논문

The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors
Document Type
Periodical
Author
Source
IEEE Transactions on Parts, Hybrids, and Packaging IEEE Trans. Parts, Hybrids, Packag. Parts, Hybrids, and Packaging, IEEE Transactions on. 11(2):108-110 Jun, 1975
Subject
Components, Circuits, Devices and Systems
Gases
Capacitors
Temperature
Dielectric breakdown
Aluminum
Breakdown voltage
Testing
Engine cylinders
Voltage control
Dielectric films
Language
ISSN
0361-1000
1558-2469
Abstract
The use of Fr-14 (CF 4 ) and Fr-116 (C 2 F 6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air.