학술논문

Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Document Type
Periodical
Source
IEEE Transactions on Magnetics IEEE Trans. Magn. Magnetics, IEEE Transactions on. 32(4):2167-2170 Jul, 1996
Subject
Fields, Waves and Electromagnetics
Testing
Spectroscopy
Coils
Superconducting magnets
Copper
Conductors
Boring
Insulation
Steel
Language
ISSN
0018-9464
1941-0069
Abstract
The 4 GeV/c high resolution spectrometers of the CEBAF experimental Hall A require two mirror imaged superconducting quadrupole magnets of cosine 2/spl theta/ configuration. These magnets, built at Saclay, have the following parameters: 300 mm clear bore, 948 mm magnetic length, quadrupole field gradient 8.5 T/m with a 1/spl times/10/sup -5/ uniformity. The paper gives an overview of the design and describes construction technology and test results: coil dimensions, harmonics content, gradient measurement.