학술논문

A Nonlinear Dynamics-Based Estimator for Functional Electrical Stimulation: Preliminary Results From Lower-Leg Extension Experiments
Document Type
Periodical
Source
IEEE Transactions on Neural Systems and Rehabilitation Engineering IEEE Trans. Neural Syst. Rehabil. Eng. Neural Systems and Rehabilitation Engineering, IEEE Transactions on. 25(12):2365-2374 Dec, 2017
Subject
Bioengineering
Computing and Processing
Robotics and Control Systems
Signal Processing and Analysis
Communication, Networking and Broadcast Technologies
Estimation
Jacobian matrices
Iron
Knee
Noise measurement
Musculoskeletal system
Legged locomotion
State-dependent coefficient
extended kalman filter
rotation matrix
functional electrical stimulation
nonlinear state estimator
Language
ISSN
1534-4320
1558-0210
Abstract
Miniature inertial measurement units (IMUs) are wearable sensors that measure limb segment or joint angles during dynamic movements. However, IMUs are generally prone to drift, external magnetic interference, and measurement noise. This paper presents a new class of nonlinear state estimation technique called state-dependent coefficient (SDC) estimation to accurately predict joint angles from IMU measurements. The SDC estimation method uses limb dynamics, instead of limb kinematics, to estimate the limb state. Importantly, the nonlinear limb dynamic model is formulated into state-dependent matrices that facilitate the estimator design without performing a Jacobian linearization. The estimation method is experimentally demonstrated to predict knee joint angle measurements during functional electrical stimulation of the quadriceps muscle. The nonlinear knee musculoskeletal model was identified through a series of experiments. The SDC estimator was then compared with an extended kalman filter (EKF), which uses a Jacobian linearization and a rotation matrix method, which uses a kinematic model instead of the dynamic model. Each estimator’s performance was evaluated against the true value of the joint angle, which was measured through a rotary encoder. The experimental results showed that the SDC estimator, the rotation matrix method, and EKF had root mean square errors of 2.70°, 2.86°, and 4.42°, respectively. Our preliminary experimental results show the new estimator’s advantage over the EKF method but a slight advantage over the rotation matrix method. However, the information from the dynamic model allows the SDC method to use only one IMU to measure the knee angle compared with the rotation matrix method that uses two IMUs to estimate the angle.