학술논문

The Quench Recovery Analysis of the JT-60SA Superconducting Magnet
Document Type
Periodical
Source
IEEE Transactions on Applied Superconductivity IEEE Trans. Appl. Supercond. Applied Superconductivity, IEEE Transactions on. 30(4):1-4 Jun, 2020
Subject
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Helium
Coils
Superconducting magnets
Cooling
Temperature distribution
Refrigerators
Conductors
JT-60SA
central solenoid
quench recovery
refrigerator operation
SuperMagnet code
Language
ISSN
1051-8223
1558-2515
2378-7074
Abstract
A CS module is composed of the 52 layers pancake coils. The 26 helium flowing paths are in a one module. The refrigerator supplies helium at 4.4 K to each flowing paths in nominal operation. In case of a quench, the refrigerator stops helium supply in order to shut out large heat load from the quenched magnet. The temperature distribution of the quenched CS will be smoothed by a heat conduction between each pancake coils while helium is stopped. Helium will be supplied again when the magnet pressure become low enough. The temperature distribution changes are calculated by using SuperMagnet.