학술논문

Experience with magnetic shielding of a large scale accelerator
Document Type
Conference
Source
PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268) Particle accelerator conference Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001. 5:3371-3373 vol.5 2001
Subject
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Nuclear Engineering
Robotics and Control Systems
Magnetic shielding
Large-scale systems
Acceleration
Magnetic field measurement
Coils
Structural beams
Extraterrestrial measurements
Saturation magnetization
Manufacturing
Accelerator magnets
Language
Abstract
It is not unusual to place multiple accelerators in a common enclosure to save on civil construction costs. This often complicates operations, especially if accelerators are affecting each other. At Fermilab, the influence of a rapidly cycling Main Injector (MI) synchrotron on an antiproton storage ring (Recycler), placed in a common tunnel, was initially found to be unacceptable for a reliable operation of the Recycler. Initial closed orbit excursions in the Recycler ring during the MI ramp were in excess of 5 mm (rms). This paper describes a shielding technique, used to reduce these orbit excursions by a factor of five.