학술논문

MGy Radiation Assessment of a Space-Graded Amplifier and ADC
Document Type
Conference
Source
2015 15th European Conference on Radiation and Its Effects on Components and Systems (RADECS) Radiation and Its Effects on Components and Systems (RADECS), 2015 15th European Conference on. :1-3 Sep, 2015
Subject
Components, Circuits, Devices and Systems
Sensors
Instruments
Radiation effects
Monitoring
Annealing
Aerospace electronics
Temperature measurement
Language
Abstract
This paper shows a high total dose radiation assessment on a set of space qualified components. Two space graded COTS (Commercial off-the-shelf) components were selected and monitored under 60Co gamma radiation, namely an instrumentation amplifier and a 14 bit analogue-to-digital-converter (ADC). The specifications of these COTS components were monitored on-line with a customized test bed, up-to a total ionizing dose larger than 1 MGy and are presented in this paper.