Design and Performance of the Alignment System for the CMS Muon Endcaps
Document Type
Conference
Source
2006 IEEE Nuclear Science Symposium Conference Record Nuclear Science Symposium Conference Record, 2006. IEEE. 1:489-495 Oct, 2006
Subject
Nuclear Engineering
Power, Energy and Industry Applications
Fields, Waves and Electromagnetics
Engineered Materials, Dielectrics and Plasmas
Collision mitigation
Mesons
Optical sensors
Sensor systems
Monitoring
Charge coupled devices
Cathodes
Strips
Hardware
System testing
Language
ISSN
1082-3654
Abstract
The alignment system for the CMS Muon Endcap detector employs several hundred sensors such as optical 1-D CCD sensors illuminated by lasers and analog distance- and tilt-sensors to monitor the positions of one sixth of 468 large Cathode Strip Chambers. The chambers mounted on the endcap yoke disks undergo substantial deformation on the order of centimeters when the 4T field is switched on and off. The Muon Endcap alignment system is required to monitor chamber positions with 75-200 μm accuracy in the Rφ plane, ~400 μm in the radial direction, and ~1 mm in the z-direction along the beam axis. The complete alignment hardware for one of the two endcaps has been installed at CERN. A major system test was performed when the 4T solenoid magnet was ramped up to full field for the first time in August 2006. We present the overall system design and first results on disk deformations, which indicate that the measurements agree with expectations.