학술논문

Improved Readout Screens for Gated X-Ray Intensifiers
Document Type
Conference
Source
IEEE Conference Record - Abstracts. 2005 IEEE International Conference on Plasma Science Plasma Science, 2005. ICOPS '05. IEEE Conference Record - Abstracts. IEEE International Conference on. :158-158 Jun, 2005
Subject
Engineered Materials, Dielectrics and Plasmas
Fields, Waves and Electromagnetics
Components, Circuits, Devices and Systems
Power, Energy and Industry Applications
Nuclear Engineering
Plasma measurements
Spectroscopy
Plasma diagnostics
Laboratories
Plasma confinement
Plasma x-ray sources
Plasma sources
Energy resolution
Detectors
Crystals
Language
ISSN
0730-9244
Abstract
Summary form only given. High-energy-density-physics and inertial confinement fusion experiments done on Z pinch machines and laser facilities often use gated X-ray intensifiers (GXI) as the primary diagnostic. Improvements in resolution and background noise can be achieved with improved phosphor screens. We have developed several new sources for readout screens. Data will be presented that show resolution limits, signal to noise and luminosity at wavelengths useful for large area CCD readouts