학술논문

Weighting-Based Deep Ensemble Learning for Recognition of Interventionalists’ Hand Motions During Robot-Assisted Intravascular Catheterization
Document Type
Periodical
Source
IEEE Transactions on Human-Machine Systems IEEE Trans. Human-Mach. Syst. Human-Machine Systems, IEEE Transactions on. 53(1):215-227 Feb, 2023
Subject
Communication, Networking and Broadcast Technologies
Components, Circuits, Devices and Systems
Signal Processing and Analysis
Robotics and Control Systems
Power, Energy and Industry Applications
General Topics for Engineers
Computing and Processing
Feature extraction
Catheterization
Motion segmentation
Navigation
Surgery
Robot sensing systems
Manuals
Deep learning
hand motion classification
robot- assisted navigation
robotic catheterization
surface electro- myography (sEMG) control
Language
ISSN
2168-2291
2168-2305
Abstract
Robot-assisted intravascular interventions have evolved as unique treatments approach for cardiovascular diseases. However, the technology currently has low potentials for catheterization skill evaluation, slow learning curve, and inability to transfer experience gained from manual interventions. This study proposes a new weighting-based deep ensemble model for recognizing interventionalists' hand motions in manual and robotic intravascular catheterization. The model has a module of neural layers for extracting features in electromyography data, and an ensemble of machine learning methods for classifying interventionalists' hand gestures as one of the six hand motions used during catheterization. A soft-weighting technique is applied to guide the contributions of each base learners. The model is validated with electromyography data recorded during in-vitro and in-vivo trials and labeled as many-to-one sequences. Results obtained show the proposed model could achieve 97.52% and 47.80% recognition performances on test samples in the in-vitro and in-vivo data, respectively. For the latter, transfer learning was applied to update weights from the in-vitro data, and the retrained model was used for recognizing the hand motions in the in-vivo data. The weighting-based ensemble was evaluated against the base learners and the results obtained shows it has a more stable performance across the six hand motion classes. Also, the proposed model was compared with four existing methods used for hand motion recognition in intravascular catheterization. The results obtained show our model has the best recognition performances for both the in-vitro and in-vivo catheterization datasets. This study is developed toward increasing interventionalists' skills in robot-assisted catheterization.