학술논문

Prospective evaluation of interrater agreement between EEG technologists and neurophysiologists
Document Type
article
Source
Scientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
Subject
Medicine
Science
Language
English
ISSN
2045-2322
Abstract
Abstract We aim to prospectively investigate, in a large and heterogeneous population, the electroencephalogram (EEG)-reading performances of EEG technologists. A total of 8 EEG technologists and 5 certified neurophysiologists independently analyzed 20-min EEG recordings. Interrater agreement (IRA) for predefined EEG pattern identification between EEG technologists and neurophysiologits was assessed using percentage of agreement (PA) and Gwet-AC1. Among 1528 EEG recordings, the PA [95% confidence interval] and interrater agreement (IRA, AC1) values were as follows: status epilepticus (SE) and seizures, 97% [96–98%], AC1 kappa = 0.97; interictal epileptiform discharges, 78% [76–80%], AC1 = 0.63; and conclusion dichotomized as “normal” versus “pathological”, 83.6% [82–86%], AC1 = 0.71. EEG technologists identified SE and seizures with 99% [98–99%] negative predictive value, whereas the positive predictive values (PPVs) were 48% [34–62%] and 35% [20–53%], respectively. The PPV for normal EEGs was 72% [68–76%]. SE and seizure detection were impaired in poorly cooperating patients (SE and seizures; p