Abstract
Abstract Background To investigate the validation of phenol red thread (PRT) test in a Chinese population by evaluating the intraobserver repeatability and interobserver reproducibility, determining correlations between the PRT test and other dry eye disease (DED) parameters including tear meniscus height (TMH) and Schirmer I test, and testing the accuracy of diagnosing DED when using the PRT test alone. Methods A total of 108 eyes were involved in this prospective and diagnostic study, and were divided into two groups (with and without DED). Each subject underwent a series of ocular surface examinations, including Ocular Surface Disease Index (OSDI) questionnaire, non-invasive tear breakup time (NIBUT), tear meniscus height (TMH) assessment, PRT test, fluorescein tear breakup time (FBUT), corneal fluorescein staining and Schirmer I test. Results In the experimental group and the control group, the intra-class correlation coefficients (ICCs) of the repeatability were 0.747 and 0.723, respectively (all P