Impact of process parameters and design options on heat leaks of straight cryogenic distribution lines
Document Type
article
Source
Physical Review Accelerators and Beams, Vol 20, Iss 3, p 033202 (2017)
Subject
Nuclear and particle physics. Atomic energy. Radioactivity
QC770-798
Language
English
ISSN
2469-9888
Abstract
The Future Circular Collider (FCC) accelerator will require a helium distribution system that will exceed the presently exploited transfer lines by almost 1 order of magnitude. The helium transfer line will contain five process pipes protected against heat leaks by a common thermal shield. The design pressure of the FCC process pipe with supercritical helium will be equal to 5.0 MPa, significantly exceeding the 2.0 MPa value in the present, state-of–art transfer lines. The increase of the design pressure requires construction changes to be introduced to the support system, the vacuum barriers and the compensation bellows. This will influence heat flows to the helium. The paper analyses the impact of the increased design pressure on the heat flow. The paper also offers a discussion of the design modifications to the compensation system, including the replacement of stainless steel with Invar®—aimed at mitigating the pressure increase.